Name
|
Description
|
|
FetchIntervalAvg
|
Return the average power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
FetchIntervalFilteredMax
|
Return the maximum filtered power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
FetchIntervalFilteredMin
|
Return the minmum power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
FetchIntervalMax
|
Return the maximum instantaneous power or voltage in the time interval between marker1 and marker 2. The units will be the same as the specified channel.
|
|
FetchIntervalMaxAvg
|
Return maximum of the average power trace between MK1 and MK2. The units will be the same as the specified channel.
|
|
FetchIntervalMin
|
Return the minimum instantaneous power or voltage in the time interval between marker1 and marker 2. The units will be the same as the specified channel.
|
|
FetchIntervalMinAvg
|
Return minimum of the average power trace between MK1 and MK2. The units will be the same as the specified channel.
|
|
FetchIntervalPkToAvg
|
Return the peak-to-average ratio of the power or voltage between marker 1 and marker 2. The units are dB for logarithmic channel units or percent for linear channel units.
|
|
ReadIntervalAvg
|
Return the average power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
ReadIntervalFilteredMax
|
Return the maximum filtered power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
ReadIntervalFilteredMin
|
Return the minmum power or voltage in the time interval between marker 1 and marker 2. The units will be the same as the specified channel.
|
|
ReadIntervalMax
|
Return the maximum instantaneous power or voltage in the time interval between marker1 and marker 2. The units will be the same as the specified channel.
|
|
ReadIntervalMaxAvg
|
Return maximum of the average power trace between MK1 and MK2. The units will be the same as the specified channel.
|
|
ReadIntervalMin
|
Return the minimum instantaneous power or voltage in the time interval between marker1 and marker 2. The units will be the same as the specified channel.
|
|
ReadIntervalMinAvg
|
Return minimum of the average power trace between MK1 and MK2. The units will be the same as the specified channel.
|
|
ReadIntervalPkToAvg
|
Return the peak-to-average ratio of the power or voltage between marker 1 and marker 2. The units are dB for logarithmic channel units or percent for linear channel units.
|