collapse_allSyntax

Top  Previous  Next

 

Boonton55xxx IVI Driver Reference


 

IviPwrMeterTriggerSourceEnum Enumeration


See Also



IVI PwrMeter class-compliant values for Trigger Source

Namespace: Ivi.PwrMeter.Interop

Assembly: Ivi.PwrMeter.Interop (in Ivi.PwrMeter.Interop.DLL)

Visual Basic

Public Enumeration IviPwrMeterTriggerSourceEnum

C#

public enum IviPwrMeterTriggerSourceEnum

Visual C++

public enum class IviPwrMeterTriggerSourceEnum

 

collapse_allMembers


Member name

Value

Description


IviPwrMeterTriggerSourceImmediate

0x00000001

The power meter exits the Wait-For-Trigger state immediately after entering. It does not wait for a trigger of any kind.


IviPwrMeterTriggerSourceExternal

0x00000002

The power meter exits the Wait-For-Trigger state when a trigger occurs on the external trigger input.


IviPwrMeterTriggerSourceInternal

0x00000003

The power meter exits the Wait-For-Trigger state when an internal trigger event occurs on the measurement signal.


IviPwrMeterTriggerSourceSoftware

0x00000004

The power meter exits the Wait-For-Trigger state when it receives a software trigger.


IviPwrMeterTriggerSourceTTL0

0x00000064

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL0.


IviPwrMeterTriggerSourceTTL1

0x00000065

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL1.


IviPwrMeterTriggerSourceTTL2

0x00000066

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL2.


IviPwrMeterTriggerSourceTTL3

0x00000067

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL3.


IviPwrMeterTriggerSourceTTL4

0x00000068

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL4.


IviPwrMeterTriggerSourceTTL5

0x00000069

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL6.


IviPwrMeterTriggerSourceTTL6

0x0000006A

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL6.


IviPwrMeterTriggerSourceTTL7

0x0000006B

The power meter exits the Wait-For-Trigger state when it receives a trigger on TTL7.


IviPwrMeterTriggerSourceECL0

0x000000C8

The power meter exits the Wait-For-Trigger state when it receives a trigger on ECL0.


IviPwrMeterTriggerSourceECL1

0x000000C9

The power meter exits the Wait-For-Trigger state when it receives a trigger on ECL1.


IviPwrMeterTriggerSourcePXIStar

0x0000012C

The power meter exits the Wait-For-Trigger state when it receives a trigger on PXI Star trigger bus.


IviPwrMeterTriggerSourceRTSI0

0x00000190

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI0 line.


IviPwrMeterTriggerSourceRTSI1

0x00000191

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI1 line.


IviPwrMeterTriggerSourceRTSI2

0x00000192

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI2 line.


IviPwrMeterTriggerSourceRTSI3

0x00000193

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI3 line.


IviPwrMeterTriggerSourceRTSI4

0x00000194

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI4 line.


IviPwrMeterTriggerSourceRTSI5

0x00000195

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTS5 line.


IviPwrMeterTriggerSourceRTSI6

0x00000196

The power meter exits the Wait-For-Trigger state when it receives a trigger on the RTSI6 line.

collapse_allSee Also

Reference

Ivi.PwrMeter.Interop Namespace

Footer image

Copyright 2013-16 Boonton. All rights reserved.