Tree Node: \Boonton55xxx\Instrument Specific\Channel
|
Name |
Description |
|
Performs a multi-point sensor gain calibration of the selected sensor with the internal calibrator. This method is not valid for 55 Series USB power meters. |
||
Performs a multi-point sensor gain calibration of the selected sensor with the internal calibrator and returns true if successful. This method is not valid for 55 Series USB power meters. |
||
Sets the 55 series power meter to a buffered capture mode and disables real time processing. |
||
Performs a calibration at a fixed frequency and level. |
||
Performs a calibration at a fixed frequency and level and returns true if successful. |
||
Set or return the number of traces averaged together to form the measurement result on the selected channel. |
||
Set or return the sensor video bandwidth for the selected sensor. |
||
Return current sensor internal temperature in degrees C |
||
Set or return the measurement state of the selected channel. When the value is true, the channel performs measurements; when the value is false, the channel is disabled and no measurements are performed. |
||
Set or return the current setting of the integration filter on the selected channel. |
||
Set or return the current length of the integration filter on the selected channel. |
||
Returns the firmware version of the power meter associated with this channel. |
||
Returns an XML document containing settings and readings obtained using the SaveToMemoryChannel method. |
||
Model number of the meter connected to the specified channel. |
||
Set or return the number of min/max traces averaged together to form the peak hold measurement results on the selected channel. |
||
Sets or returns whether peak hold decay automatically tracks trace averaging. If set to true, the peak hold decay and trace averaging values are the same. If set to false, peak hold decay is indepedent. |
||
Serial number of the sensor. |
||
Set or return units for the selected channel. Voltage is calculated with reference to the sensor input impedance. Note that for ratiometric results, logarithmic units will always return dBr (dB relative) while linear units return percent. |
||
Loads the named memory channel using the given archive. If the memory channel does not exist, one is created. |
||
Saves the given channel to a memory channel. If the memory channel does not exist, a new one is created. |
||
Instructs power meter to save the value of fixed cal, zero, and skew values. |
||
Set or return the number of traces averaged together to form the measurement result on the selected channel. |
||
Set or return the sensor video bandwidth for the selected sensor. |
||
Set or return the measurement state of the selected channel. When the value is true, the channel performs measurements; when the value is false, the channel is disabled and no measurements are performed. |
||
Set or return the current setting of the integration filter on the selected channel. |
||
Set or return the current length of the integration filter on the selected channel. |
||
Sets or returns whether peak hold decay automatically tracks trace averaging. If set to true, the peak hold decay and trace averaging values are the same. If set to false, peak hold decay is indepedent. |
||
Set or return units for the selected channel. Voltage is calculated with reference to the sensor input impedance. Note that for ratiometric results, logarithmic units will always return dBr (dB relative) while linear units return percent. |
||
Performs a zero offset null adjustment. |
||
Performs a zero offset null adjustment and returns true if successful. |
Name |
Description |
|
Set or return the number of traces averaged together to form the measurement result on the selected channel. |
||
Set or return the sensor video bandwidth for the selected sensor. |
||
Return current sensor internal temperature in degrees C |
||
Set or return the measurement state of the selected channel. When the value is true, the channel performs measurements; when the value is false, the channel is disabled and no measurements are performed. |
||
Set or return the current setting of the integration filter on the selected channel. |
||
Set or return the current length of the integration filter on the selected channel. |
||
Returns the firmware version of the power meter associated with this channel. |
||
Returns the FPGA version for the power meter associated with this channel. |
||
Model number of the meter connected to the specified channel. |
||
Set or return the number of min/max traces averaged together to form the peak hold measurement results on the selected channel. |
||
Sets or returns whether peak hold decay automatically tracks trace averaging. If set to true, the peak hold decay and trace averaging values are the same. If set to false, peak hold decay is indepedent. |
||
Serial number of the sensor. |
||
Set or return units for the selected channel. Voltage is calculated with reference to the sensor input impedance. Note that for ratiometric results, logarithmic units will always return dBr (dB relative) while linear units return percent. |